The table below gives the maximum effective wall heights for the different precast concrete panel types available based on the anticipated profile and additional surcharged loading and, in the case of horizontal panels, the span between support columns.
Assuming 1800kg/m backfill material with 30 deg internal angle shear resistance and free draining in all cases.
|
Wall Type |
Section Size |
Full Surcharged profile |
Level Fill Profile |
Level Fill with 10kN/m2 Surcharge Load |
|---|---|---|---|---|
|
Boot Wall Panels |
180mm to 300mm |
Project specific design |
Project specific design |
Project specific design |
|
L Shape Panels |
Standard profile |
3.0m |
3.8m |
3.2m |
|
Vertical Cantilever |
145mm |
2.8m |
3.5m |
3.0m |
|
Vertical Cantilever |
180mm |
3.0m |
3.9m |
3.4m |
|
Vertical Cantilever |
280mm |
4.4m |
5.5m |
5.0m |
|
4.0m c/c Horizontal |
145mm |
3.5m |
7.0m |
5.5m |
|
5.0m c/c Horizontal |
145mm |
2.2m |
5.2m |
4.2m |
|
6.0m c/c Horizontal |
145mm |
1.5m |
3.5m |
2.9m |
|
4.0m c/c Horizontal |
180mm |
5.3m |
10.0m |
9.2m |
|
5.0m c/c Horizontal |
180mm |
3.4m |
7.5m |
6.0m |
|
6.0m c/c Horizontal |
180mm |
2.3m |
5.2m |
4.2m |
|
6.0m c/c Horizontal |
280mm |
4.5m |
10.0m |
7.0m |