PRECAST CONCRETE PANEL DESIGN DATA

The following table provides a basic outline of the technical specifications for our prestressed concrete panels. More detailed information is available on request.

 

Concrete Mix
Minimum compressive strength 28 day - 60N/mm²

Water / Cement Ratio

Maximum 0.45
Prestressing Strand
9.6mm Diameter-Indented  70% Initial Force
Unit Dimensions  

Thickness

95mm, 145mm and 180mm
Width
500mm, 600mm, 700mm*, 1000mm,1200mm, 1500mm
Length
any size up to 8m dependant upon handling & application
Max Service Load
13.9 kN-m
95mm Thick
60.8 kN-m single loading,  55.8 kN-m double loading

145mm Thick

89.2 kN-m single loading,  80.7 kN-m double loading

180mm Thick

Unit Weight  

95mm thick

220 kg/m²

145mm thick

345 kg/m²

180mm thick

428 kg/m²